Remote Electrical Downtilt System Handbook Section 2– Teletilt
®
RET System Components in Detail
Bulletin 639519 • Revision D May 2009 2-5
2.4 Lightning Protection Unit
The lightning protection unit, ATLP200-001, is recommended
to provide added surge protection to any RET device, es-
pecially rack mount controllers. This unit must be grounded
using the 602299 grounding kit. It has 8–Pin male and female
interfaces to feed data and power through the AISG compliant
RET control cable. See Figure 2-7.
2.5 RET Cable Grounding Kit
As part of a system, RET cabling requires grounding and
line protection at the bottom of the tower with the use of an
ATLP200-001 lightning protection unit or ATJB200-A01 series
junction box. Andrew also recommends the use of the ATGK-001
grounding kit for every 60m of AISG RET control cable run.
The ATGK-001 grounding kit is designed to capture and
ground the cables at the junction where two cables are daisy-
chained. This means that for a 120 m run, you will use two 60
m cables (ATCB-B01-060) with the ATGK-001 grounding kit
in the middle. Kit includes a clamp module, a ground cable,
and hardware for connection to the main ground bus.
Note: AISG control systems need to be grounded at
one of these locations:
1. On the top of the site, grounding either the top SBT,
TMA, junction box, or using the ATGK-001 RET
cable grounding kit.
2. At the bottom of the site, grounding either the bot-
tom SBT, junction box, lightning protection box, the
dc 2.1 bias tee, or using the ATGK-001 RET cable
grounding kit.
3. Grounding every 60 m for the cable length using
the ATGK-001 RET cable grounding kit.
2.6 RET Equipment Grounding Kit
The 602299 grounding kit provides grounding of a RET
component, e.g. controller, lightning protection box, junction
box, smart bias tee, etc.
Figure 2-7. ATLP200-001
Lightning Protection Unit.
Figure 2-8. ATGK-001
RET Control Cable Grounding Kit.
Figure 2-9. 602299
RET Equipment Grounding Kit.
Grounding
Lug
Grounding
Cable