Remote Electrical Downtilt System Handbook Section 2– Teletilt
®
RET System Components in Detail
Bulletin 639519 • Revision D May 2009 2-11
Breakout Box (ATTK-BB)
The breakout box enables short or open conditions on the individual AISG RET control cable without
cutting into the cable. See Figure 2-18 for breakout box features.
Figure 2-18. ATTK-BB Breakout Box Unit.
Press switch to OFF position to create
an open in the cable line (with cable
attached to both ends of breakout box).
Insert test leads into
the locking sockets
to perform tests.
Male
Connection
Female
Connection
Testing Sockets
for Male Connection
Testing Sockets
for Female Connection
RS–485
Data Lines
Power Traveling to
RET Device
Power Traveling to
RET Device
Power Traveling away
from RET Device